FHIR Osiris Implementation Guide
1.1.0 - trial-implementation
This page is part of the OSIRIS FHIR Implementation Guide (v1.1.0: Release) based on FHIR (HL7® FHIR® Standard) R4. This is the current published version. For a full list of available versions, see the Directory of published versions
<ImagingStudy xmlns="http://hl7.org/fhir">
<id value="fhir-osiris-example-imagingstudy-pt-nm"/>
<meta>
<profile
value="https://ig-osiris.cancer.fr/ig/osiris/StructureDefinition/onco-imagingstudy"/>
</meta>
<text>
<status value="extensions"/>
<div xmlns="http://www.w3.org/1999/xhtml"><p class="res-header-id"><b>Generated Narrative: ImagingStudy fhir-osiris-example-imagingstudy-pt-nm</b></p><a name="fhir-osiris-example-imagingstudy-pt-nm"> </a><a name="hcfhir-osiris-example-imagingstudy-pt-nm"> </a><a name="fhir-osiris-example-imagingstudy-pt-nm-en-US"> </a><div style="display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%"><p style="margin-bottom: 0px"/><p style="margin-bottom: 0px">Profil: <a href="StructureDefinition-onco-imagingstudy.html">Imaging Study</a></p></div><p><b>identifier</b>: 1.3.6.1.4.1.14519.5.2.1.5168.1900.291490762800233473213844289511</p><p><b>status</b>: Available</p><p><b>modality</b>: <a href="http://terminology.hl7.org/6.2.0/CodeSystem-umls.html#umls-C0439673">Unified Medical Language System C0439673</a>: C0439673</p><p><b>subject</b>: <a href="Patient-STS-028.html">Patient Anonyme Unknown, Date de Naissance :1000-01-01</a></p><p><b>started</b>: 2004-01-27</p><p><b>endpoint</b>: <a href="Endpoint-fhir-osiris-example-imagingendpoint-pt-nm.html">Endpoint ['Soft-tissue-Sarcoma/STS_028/01-27-2004-NA-PET CT with registered MR-89511/4.000000-LEGS2DAC-91862/1-036.dcm']</a></p><p><b>numberOfSeries</b>: 999999</p><p><b>reasonReference</b>: <a href="Observation-fhir-osiris-example-analysis-pt-nm.html">Observation Imaging</a></p><p><b>description</b>: CT PET with registered MR </p><blockquote><p><b>series</b></p><blockquote><p><b>Imaging Settings</b></p><blockquote><p><b>url</b></p>slice_thickness</blockquote><p><b>value</b>: 3.2700</p><blockquote><p><b>url</b></p>pixel_spacing</blockquote><p><b>value</b>: [5.46875, 5.46875]</p><blockquote><p><b>url</b></p>rows</blockquote><p><b>value</b>: 128</p><blockquote><p><b>url</b></p>columns</blockquote><p><b>value</b>: 128</p><blockquote><p><b>url</b></p>imaging_injection</blockquote><p><b>value</b>: <a href="MedicationAdministration-fhir-osiris-example-injection-pt-nm.html">MedicationAdministration : status = completed; medication[x] = ->Medication ; effective[x] = 1000-01-01</a></p><p><b>attenuation_correction_method</b>: measured,, 0.096000 cm-1</p><p><b>reconstruction_method</b>: OSEM</p><p><b>scatter_correction_method</b>: Convolution subtraction</p><blockquote><p><b>url</b></p>pt_nm_image</blockquote></blockquote><blockquote><p><b>Weight and Height at the time of the Serie</b></p><ul><li>patient_weight: 58</li><li>patient_height: 1.57</li></ul></blockquote><p><b>uid</b>: 1.3.6.1.4.1.14519.5.2.1.5168.1900.250501927430896548137411991862</p><p><b>number</b>: 4</p><p><b>modality</b>: dicom PT: PT</p><p><b>description</b>: LEGS_2D_AC PET CT with registered MR</p><p><b>numberOfInstances</b>: 999999</p><p><b>bodySite</b>: <a href="http://snomed.info/id/66019005">SNOMED CT 66019005</a>: Extremity</p><p><b>started</b>: 2004-01-27</p><h3>Performers</h3><table class="grid"><tr><td style="display: none">-</td><td><b>Actor</b></td></tr><tr><td style="display: none">*</td><td><a href="Device-fhir-osiris-example-imagingdevice-pt-nm.html">Device : manufacturer = GE MEDICAL SYSTEMS</a></td></tr></table><h3>Instances</h3><table class="grid"><tr><td style="display: none">-</td><td><b>Uid</b></td><td><b>SopClass</b></td></tr><tr><td style="display: none">*</td><td>1.3.6.1.4.1.14519.5.2.1.5168.1900.309323295882753345616672095692</td><td>[not stated] table_B.5-1#1.2.840.10008.5.1.4.1.1.128: Positron Emission Tomography Image Storage</td></tr></table></blockquote></div>
</text>
<identifier>
<value
value="1.3.6.1.4.1.14519.5.2.1.5168.1900.291490762800233473213844289511"/>
</identifier>
<status value="available"/>
<modality>
<system value="http://terminology.hl7.org/CodeSystem/umls"/>
<code value="C0439673"/>
</modality>
<subject>🔗
<reference value="Patient/STS-028"/>
</subject>
<started value="2004-01-27"/>
<endpoint>🔗
<reference value="Endpoint/fhir-osiris-example-imagingendpoint-pt-nm"/>
</endpoint>
<numberOfSeries value="999999"/>
<reasonReference>🔗
<reference value="Observation/fhir-osiris-example-analysis-pt-nm"/>
</reasonReference>
<description value="CT PET with registered MR "/>
<series>
<extension
url="https://ig-osiris.cancer.fr/ig/osiris/StructureDefinition/imaging-settings">
<extension url="slice_thickness">
<valueString value="3.2700"/>
</extension>
<extension url="pixel_spacing">
<valueString value="[5.46875, 5.46875]"/>
</extension>
<extension url="rows">
<valueInteger value="128"/>
</extension>
<extension url="columns">
<valueInteger value="128"/>
</extension>
<extension url="imaging_injection">
<valueReference>🔗
<reference
value="MedicationAdministration/fhir-osiris-example-injection-pt-nm"/>
</valueReference>
</extension>
<extension url="pt_nm_image">
<extension url="attenuation_correction_method">
<valueString value="measured,, 0.096000 cm-1"/>
</extension>
<extension url="reconstruction_method">
<valueString value="OSEM"/>
</extension>
<extension url="scatter_correction_method">
<valueString value="Convolution subtraction"/>
</extension>
</extension>
</extension>
<extension
url="https://ig-osiris.cancer.fr/ig/osiris/StructureDefinition/series-weightheigt">
<extension url="patient_weight">
<valueDecimal value="58"/>
</extension>
<extension url="patient_height">
<valueDecimal value="1.57"/>
</extension>
</extension>
<uid
value="1.3.6.1.4.1.14519.5.2.1.5168.1900.250501927430896548137411991862"/>
<number value="4"/>
<modality>
<system value="https://dicom.nema.org/medical/dicom"/>
<code value="PT"/>
</modality>
<description value="LEGS_2D_AC PET CT with registered MR"/>
<numberOfInstances value="999999"/>
<bodySite>
<system value="http://snomed.info/sct"/>
<code value="66019005"/>
</bodySite>
<started value="2004-01-27"/>
<performer>
<actor>🔗
<reference value="Device/fhir-osiris-example-imagingdevice-pt-nm"/>
</actor>
</performer>
<instance>
<uid
value="1.3.6.1.4.1.14519.5.2.1.5168.1900.309323295882753345616672095692"/>
<sopClass>
<code value="table_B.5-1#1.2.840.10008.5.1.4.1.1.128"/>
<display value="Positron Emission Tomography Image Storage"/>
</sopClass>
</instance>
</series>
</ImagingStudy>